Working principle of MCR type SVC The MCR type dynamic reactive power compensation device (SVC) is mainly composed of three parts, FC filter system, MCR thyristor controlled magnetron electric hanger system and control protection system. The FC filter system is used to provide capacitive reactive power and filter harmonics; the MCR thyristor-controlled magnetron reactor system is used to balance the inductive reactive power generated by load fluctuations in the system. By adjusting the trigger angle of the thyristor, the control The current flowing through the reactor achieves the purpose of controlling reactive power. The dynamic reactive power compensation device MCR-SVC device changes the reactive power (inductance) of the reactor according to the change of the reactive power of the load. After the MCR-SVC is put into operation, it dynamically tracks how the power of the load changes, the power factor is always kept at the set value, and the voltage hardly fluctuates, so as to achieve the purpose of reactive power compensation and filtering, so as to suppress the system voltage fluctuation caused by load changes and Flicker.
product model
Model Description
Technical Parameters
Device Features ●The control system adopts full digital control based on DSP, and the dynamic response time is less than 0.1s. ●The control system has a complete self-diagnosis function to realize real-time monitoring and remote monitoring; ●A variety of control functions and options can be selected and added according to customer requirements; ●The information system is transmitted through the optical cable, the transmission speed is fast, and the anti-interference ability is strong; ●The silicon controlled rectifier is installed in the control circuit, and the withstand voltage is only 1% of the main circuit, with high reliability; Low harmonic content, the total current distortion rate THDI of the three-phase delta connection system is less than 5%; ●Standardized frame structure, easy to install and maintain; ●MCR is partly maintenance-free; ●It can run directly on any voltage level grid and is easy to install and debug; ●After the device is put into operation, the power factor can reach more than 0.95, reducing voltage fluctuation and flicker, and the three-phase balance meets the national standard and IEC standard.
Other parameters
Conditions of Use ●Installation and operation environment, the indoor installation does not exceed -5°C~+40°C; ●Outdoor installation does not exceed -40°C~+45°C ●There is no severe mechanical vibration, no harmful gas and steam, no conductive or explosive dust in the installation and operation area.